GATE CE 2026 (S2) — Question 48

Steel StructuresConcept of plastic analysis – beams and portal framesNAT2 marksMedium

A 250 mm wide × 600 mm deep rectangular concrete beam is prestressed by means of 4 high-tensile tendons, each of 14 mm diameter. The centre of the tendons is 200 mm from the soffit of the beam. The effective stress in each tendon is 700 N/mm\(^2\). The maximum bending moment (in kN-m), that can be applied to the section without causing tension at the soffit of the beam due to prestressing only, is ______ (rounded off to one decimal place). Use \(\pi = 3.14\)