A belt-driven DC shunt generator running at 300 RPM delivers 100 kW to a 200 V DC grid. It continues to run as a motor when the belt breaks, taking 10 kW from the DC grid. The armature resistance is 0.025 Ω, field resistance is 50 Ω, and brush drop is 2 V. Ignoring armature reaction, the speed of the motor is __________ RPM. (Round off to 2 decimal places.)
GATE EE 2021 — Question 54
Electrical MachinesDC machines: separately excited, series and shunt, motoring and generating mode of operation and their characteristics, speed control of dc motorsNAT2 marksMedium
A GATE question every morning
One real past-paper question every morning for your branch, answer hidden until you tap. Free on Telegram.
More on DC machines: separately excited, series and shunt, motoring and generating mode of operation and their characteristics, speed control of dc motors
- GATE EE 2025 · Q44A DC series motor with negligible series resistance is running at a certain speed driving a load, where the load torque varies as cube of t…
- GATE EE 2023 · Q30A separately excited DC motor rated 400 V, 15 A, 1500 RPM drives a constant torque load at rated speed operating from 400 V DC supply drawi…
- GATE EE 2022 · Q62A 280 V, separately excited DC motor with armature resistance of 1 Ω and constant field excitation drives a load. The load torque is propor…