The fuel cost functions in rupees/hour for two 600 MW thermal power plants are given by
Plant 1:
Plant 2:
where and are power generated by plant 1 and plant 2, respectively, in MW and is constant. The incremental cost of power (λ) is 8 rupees per MWh. The two thermal power plants together meet a total power demand of 550 MW. The optimal generation of plant 1 and plant 2 in MW, respectively, are
- A200, 350
- B250, 300
- C325, 225
- D350, 200